Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	49
Date	08/12/14
Start Time	11:01:15
Diameter Midpoint
 10.9	2488.41
 11.3	129147
 11.8	557702
 12.2	552471
 12.6	567747
 13.1	603437
 13.6	622244
 14.1	645644
 14.6	668097
 15.1	686634
 15.7	719046
 16.3	734666
 16.8	744146
 17.5	745662
 18.1	725059
 18.8	707468
 19.5	688127
 20.2	648652
 20.9	608011
 21.7	558974
 22.5	503138
 23.3	441469
 24.1	374224
 25.0	314673
 25.9	259383
 26.9	203860
 27.9	155461
 28.9	117840
 30.0	82223.9
 31.1	57601.9
 32.2	38573.9
 33.4	25501.3
 34.6	16296.8
 35.9	11245.7
 37.2	7397.17
 38.5	5287.55
 40.0	3980.11
 41.4	2772.08
 42.9	2370.47
 44.5	1920.82
 46.1	1606.07
 47.8	1292.89
 49.6	1077.2
 51.4	1044.36
 53.3	867.461
 55.2	853.446
 57.3	872.629
 59.4	1009.97
 61.5	970.191
 63.8	874.197
 66.1	815.198
 68.5	718.699
 71.0	547.235
 73.7	484.451
 76.4	349.795
 79.1	315.131
 82.0	277.448
 85.1	301.488
 88.2	332.591
 91.4	451.579
 94.7	469.68
 98.2	387.07
101.8	368.749
105.5	311.961
109.4	253.98
113.4	227.161
117.6	159.608
121.9	155.511
126.3	125.964
131.0	136.628
135.8	113.237
140.7	100.929
145.9	88.1948
151.2	71.0199
156.8	76.5253
162.5	63.7442
168.5	68.0773
174.7	56.6681
181.1	52.6415
187.7	60.1252
194.6	59.3341
201.7	46.9857
209.1	35.1688
216.7	17.9584
224.7	31.6479
232.9	33.0467
241.4	37.2802
250.3	30.0261
259.5	19.5588
269.0	18.1867
278.8	24.5927
289.0	18.5236
299.6	14.8811
310.6	9.46492
322.0	13.3799
333.8	11.7179
346.0	18.7916
358.7	7.47158
371.8	10.4941
385.4	0
399.5	4.5524
414.2	9.27577
429.4	2.36344
445.1	7.1809
461.4	1.49852
478.3	8.43508
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1554
High Voltage	9861.07
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	17.1962
Mean(nm)	18.0052
Geo. Mean(nm)	17.4198
Mode(nm)	17.4658
Geo. Std. Dev.	1.28411
Total Concentration(#/cm)	1.45595e+007
Comment	